ASR-2 Integrated Management Log Messages
The Integrated Management Log (IML) or Critical Error Log for Server Health Log records
memory errors, as well as catastrophic hardware and software errors that cause the system to
fail. This information helps you quickly identify and correct the problem, thus minimizing
downtime.
You can view the IML or Critical Error Log through Compaq Insight Manager. The Diagnostics
Utility either resolves the error or suggests corrective action in systems that do not support event
logs.
The IML or Critical Error Log identifies and records all of the following errors. Each error type
is explained below.
Table 3-25
ASR-2 IML or Critical Error Log Messages
Message Description
Abnormal Program Termination The operating system has encountered an abnormal situation that has
caused a system failure.
ASR-2 detected by ROM An ASR-2 activity has been detected and logged by the system ROM.
ASR-2 Test Event The System Configuration Utility generated a test alert.
Automatic Server Recovery
Base Memory Parity Error
The system detected a data error in base memory following a reset due to
the ASR-2 timer expiration.
Automatic Server Recovery
Extended Memory Parity Error
The system detected a data error in extended memory following a reset
due to the ASR-2 timer expiration.
Automatic Server Recovery
Memory Parity Error
The system ROM was unable to allocate enough memory to create a stack.
Then it was unable to put a message on the screen or continue starting the
server.
Automatic Server Recovery
Reset Limit Reached
The maximum number of system resets due to ASR-2 timer expiration has
been reached, resulting in the loading of Compaq Utilities.
Battery Failing Low system battery warning. Replace battery within seven days to prevent
loss of nonvolatile configuration memory. Failure of the battery supporting
the systems nonvolatile RAM is imminent.
Caution: Temperature Exceeded The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto
shutdown sequence has been invoked by the operating system.
Diagnostic Error An error was detected by the Diagnostics Utility. See the specific error code
in this chapter for a detailed explanation.
Error Detected On Boot Up The server detected an error during the POST.
continued