ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-66 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-25
ASR-2 IML or Critical Error Log Messages
continued
Message Description
NMI Automatic Server
Recovery Timer Expiration
The operating system has received notice of an impending ASR-2 timer
expiration.
NMI Expansion Board Error A board on the expansion bus indicated an error condition, resulting in a
server failure.
NMI Expansion Bus Master
Time-Out
A bus master expansion board in the indicated slot did not release the bus
after its maximum time, resulting in a server failure.
NMI Expansion Bus Slave
Time-Out
A board on the expansion bus delayed a bus cycle beyond the maximum
time, resulting in a server failure.
NMI Fail-Safe Timer
Expiration
Software was unable to reset the system fail-safe timer, resulting in a
server failure.
NMI PCI Bus Parity Error A parity error was detected on the PCI bus.
NMI Processor Parity Error The processor detected a data error, resulting in a server failure.
NMI Software Generated
Interrupt Detected Error
Software indicated a system error, resulting in a server failure.
Processor Exception The indicated processor exception occurred.
Processor Prefailure A CPU has passed an internal corrected error threshold. There are
excessive internal ECC cache errors.
Required System Fan Failure The required system fan has failed. Accompanying data in the log notes if
an auto-shutdown sequence has been invoked by the operating system.
Server Manager Failure An error occurred with the Server Manager/R.
UPS A/C Line Failure Shutdown
or Battery Low
The UPS notified the operating system that the AC power line has failed.
Accompanying data indicates whether either an auto-shutdown sequence
has been invoked or the battery is nearly depleted.