ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index
2 Compaq ProLiant ML530 Servers Maintenance and Service Guide
network host name, restart
setting 3-64
network IP address, restart
setting 3-64
network IP net mask, restart
setting 3-64
network IP router address, restart
setting 3-64
network protocol, restart
setting 3-64
network status, restart
setting 3-64
OS Restart SCU Setting,
table 3-64
paging administrator 3-55
security 3-64
serial interface, restart
setting 3-64
software error
recovery 3-58
recovery boot option 3-58
recovery timeout 3-58
standby recovery
server option 3-58
server port 3-58
time-out 3-58
thermal shutdown 3-58
timer 3-59
unattended recovery 3-56
UPS shutdown 3-58
UPS shutdown threshold 3-58
automatic storage reconstruction,
defined 3-68
B
backplane board See power
backplane board
baffle
CPU fan
part number 1-5
removing 2-15
removing, illustrated 2-15
replacing 2-15
hard drive fan
part number 1-5
removing 2-16
removing, illustrated 2-16
replacing 2-16
battery power header,
identified 2-34, 4-3
battery power jumper default
setting 4-5
beeps 3-23
beeps, during POST 3-8
bezel
front door
part number 1-6
removing 2-8
removing, illustrated 2-8
replacing 2-8
rack-mount
part number 1-3
removing 2-9
removing, illustrated 2-9
replacing 2-9
blanking panel
hard drive cage, part
number 1-3
hard drive, part number 1-3
power supply
part number 1-3
removing 2-43
removing, illustrated 2-43
replacing 2-43
removable media bay, part
number 1-5
C
cable kit
power, part number 1-6
signal, part number 1-6
cable routing diagrams 2-26
cables
removal sequence 2-26
replacing 2-26
casters, part number 1-6
cautions
ADU 3-38
blanking panel 2-23
controller firmware
upgrade 3-38
data loss 3-5
defined vii
electrostatic discharge 2-4, 2-5,
2-10
Erase Utility 3-5
firmware upgrade 3-38
grounding viii
hard drive fans 2-17
memory 5-4
operating unit without
covers 2-7
overheating viii, 2-7
ventilation clearances viii
CD-ROM drive
access times 5-5
audio interface 5-5
audio out connector 5-5
cache buffer 5-5
capacity 5-5










