ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index
Index 11
power-on-password, defeating 4-4
prefailure alerting 3-73
preparation
removal and replacement
procedures 2-4
primary CPU fan
identified 2-11
primary I/O fan
identified 2-11
processor
diagnostic LED, viewing 4-8
locating primary 2-40
number supported 2-40
removing 2-40
removing, illustrated 2-40
replacing 2-40
slots, identified 2-34, 4-3
test error codes 3-25
processors
part numbers 1-5
R
rack cover kit, part number 1-3
rack warnings
equipment damage 2-6
moving 2-6
personal injury 2-6
rack loading 2-6
rack stability 2-6
rack-mount bezel
part number 1-3
removing 2-9
removing, illustrated 2-9
replacing 2-9
rack-to-tower conversion, switch
settings 4-4
Rapid Recovery Engine,
enabling 3-55
rapid recovery services 3-55
real-time clock battery
part numbers 1-6
rear panel connectors, illustrated 4-2
recommended service tools 2-1
recovery
attended 3-56
automatic 3-55, 3-56
environmental 3-56
from software error 3-56
rapid recovery services 3-55
unattended 3-56
redundant CPU fan
identified 2-11
redundant I/O fan
identified 2-11
relative humidity
system unit
specifications 5-2
remote management features,
defined 3-69
Remote Management, defined 3-72
remote power switch header
function 4-5
identified 2-34, 4-3
remote service features,
defined 3-69
Remote Utilities, accessing 3-24
removable media bay blanking panel,
part number 1-5
removable media device
location 2-19
removing 2-23
removing, illustrated 2-23
replacing 2-23
removable media devices
signal cables
identified 2-28
removal and replacement procedures,
preparation 2-4
removing
cables 2-26
CD-ROM drive 2-24
CPU fan air baffle 2-15
diskette drive 2-25
drive fan cable and cable
bracket 2-18
hard drive cage w/ backplane
board 2-21
hard drive fan air baffle 2-16
hot-plug devices 2-4
hot-plug hard drive fans 2-17
hot-plug SCSI hard drives 2-20
memory 2-39
non-hot-plug devices 2-5
PCI bracket 2-37
PCI expansion boards 2-36
PCI retainer 2-35
power backplane board 2-44
Power On/Standby switch 2-45
power supply 2-42
power supply blanking
panel 2-43
processor 2-40
removable media devices 2-23
system board 2-32
system fan cable 2-14
system fan cable bracket 2-14
replacing
cables 2-26
CD-ROM drive 2-24
CPU fan air baffle 2-15
diskette drive 2-25










