ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-6 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Running the Utilities from Diskette
Run the utilities from their individual diskettes. If you have a utility diskette newer than
the version on the SmartStart and Support Software CD, use the diskette. Always use the
newest version of the utilities.
Create a diskette version of the utility from the SmartStart and Support Software CD.
To create diskette versions of the utilities from the CD:
1. Power up from the Compaq SmartStart and Support Software CD.
2. From the Compaq System Utilities screen, select Create Support Software Disks,
then Next.
3. Select the diskette to create from the list, then follow the instructions on the screen.
Running the Utilities from the Compaq SmartStart and Support
Software CD
IMPORTANT: Only the System Configuration Utility, the Array Configuration Utility, and the Array
Diagnostic Utility can be executed from the Compaq SmartStart and Support Software CD. All other
utilities must be executed from the system partition or from diskette.
To run these utilities directly from the Compaq SmartStart and Support Software CD:
1. Power up from the Compaq SmartStart and Support Software CD.
2. From the Compaq System Utilities screen, select the utility to run, then select Next.
To execute the System Configuration Utility, select Run System Configuration
Utility.
To execute the Array Configuration Utility, select Run Array Configuration Utility.
To execute the Array Diagnostic Utility, select Run Array Diagnostic Utility.