ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
Diagnostics and Troubleshooting 3-9
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
174-Configuration/
Slot Mismatch Device
Not Found
None EISA or PCI board not found. Run the System Configuration
Utility and correct.
175-Configuration/
Slot Mismatch Device
Found
None EISA or PCI board added,
configuration not updated.
Run the System Configuration
Utility and correct.
177-Configuration
Not Complete
None Incomplete system configuration Run the System Configuration
Utility and correct.
178-Processor
Configuration Invalid
None Processor type or step does not
match configuration memory.
Run the System Configuration
Utility and correct.
180-Log Reinitialized None IML reinitializing due to log
corruption.
Event message only, no action
required.
201-Memory Error None RAM failure Run Diagnostics. Replace failed
assembly as indicated.
203-Memory
Address Error
None RAM failure Run Diagnostics. Replace failed
assembly as indicated.
207-Invalid Memory
Configuration
Check DIMM [SIMM]
Installation
None Memory module installed
incorrectly.
Verify placement of memory
modules.
208-Invalid Memory
Speed Check DIMM
[SIMM] Installation
1 long, 1 short The speed of the memory is not
compatible with the server.
Verify the speed of the memory
modules installed, then check
your servers user
documentation, and replace the
speed as indicated.
209-Memory
Detection Failure.
Check Memory
Installation
1 long, 1 short Unable to size memory. Check DIMM installation and, if
error persists, call your Compaq
service provider.
211-Cache Switch
Set Incorrectly
None Switch not set properly during
installation or upgrade.
Verify switch settings.
212-System
Processor Failed/
Mapped Out
1 short Processor in slot X failed. Run Diagnostics and replace
failed processor.
214-DC-DC
Converter Failed
None PowerSafe Module (DC-DC
Converter) failed.
Run Diagnostics. Replace failed
assembly as indicated.
218-Cache
Accelerators Not
Installed. System
Halted.
None Cache accelerators not installed
or improperly installed.
Check cache accelerator
installation.
219-Tag Update
Rules SRAM Failure.
System Halted
None Catastrophic chipset failure. Call Compaq service provider.
continued