ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
Diagnostics and Troubleshooting 3-11
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1610-Temperature
violation detected.
Waiting for system to
cool
2 short Ambient system temperature is
too hot.
Check fan and system
environment.
1611-Fan failure
detected
2 short Required fan is not installed or
spinning.
Check fans.
1611-I/O Fan (Fan X)
failure detected
2 short I/O fan has failed. Replace the failed fan.
1611-CPU Fan
(Fan X) failure
detected
2 short CPU fan has failed. Replace the failed fan.
1612-Primary
power supply failure
2 short Primary power supply has failed. Replace power supply as soon
as possible.
1613-Low System
Battery
None Real time clock system battery is
running low on power.
Run Diagnostics. Replace failed
assembly as indicated.
1615-Power Supply
Configuration Error
None Configuration requires an
additional power supply.
Install an additional
power supply.
1615-Power Supply
Failure,
Power Supply
Unplugged, or
Power Supply Fan
Failure in Bay X
None A power supply has failed. Check and replace specified
power supply.
1617-Fan controller
not responding
2 short Fan controller failure Check and replace failed
controller assembly.
1617-I/O Fan
controller not
responding
2 short I/O fan controller failure Check and replace failed
controller assembly.
1617-CPU Fan
controller not
responding
2 short CPU fan controller failure Check and replace failed
controller assembly.
1618-PCI slots
powered down.
Check PCI hot plug
enabler connectors.
None PCI hot plug enabler is missing or
failed.
Check and replace missing or
failed assembly.
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
None SCSI bus failure Run Diagnostics. Replace failed
assembly as indicated.
1621-Current SCSI
bus cable
configuration is not
recommended
None Improper SCSI bus cabling Check documentation for proper
SCSI bus cabling.
continued