ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

3-12 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1622-Internal SCSI
Jumper Board Not
Installed
None The system has detected that the
array enabler board is not
installed.
Install the array enabler board.
1703-SCSI cable
error detected.
Terminated cable
attached to output
connector of SCSI
backplane. System
halted.
None A terminated cable is attached to
the output connector of the SCSI
backplane.
Remove terminated connector.
1703-SCSI cable
error detected. Must
be configured for
single backplane,
simplex, or duplex.
System halted.
None Cables connected in unsupported
configuration.
Reconnect cables in a
supported configuration as
described in documentation.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None Incorrect cabling Ensure that the integrated SCSI
controller has SCSI termination
attached.
1720-Slot X Drive
Array – SMART Drive
Detects Imminent
Failure SCSI: Port Y:
SCSI ID X
None Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future.
If the drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing drive and restore all
data afterward. If the drive is
part of a fault-tolerant
configuration do not replace the
drive unless all other drives in
the array are online. Press F1 to
resume.
continued