ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-12 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1622-Internal SCSI
Jumper Board Not
Installed
None The system has detected that the
array enabler board is not
installed.
Install the array enabler board.
1703-SCSI cable
error detected.
Terminated cable
attached to output
connector of SCSI
backplane. System
halted.
None A terminated cable is attached to
the output connector of the SCSI
backplane.
Remove terminated connector.
1703-SCSI cable
error detected. Must
be configured for
single backplane,
simplex, or duplex.
System halted.
None Cables connected in unsupported
configuration.
Reconnect cables in a
supported configuration as
described in documentation.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None Incorrect cabling Ensure that the integrated SCSI
controller has SCSI termination
attached.
1720-Slot X Drive
Array SMART Drive
Detects Imminent
Failure SCSI: Port Y:
SCSI ID X
None Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future.
If the drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing drive and restore all
data afterward. If the drive is
part of a fault-tolerant
configuration do not replace the
drive unless all other drives in
the array are online. Press F1 to
resume.
continued