ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-16 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1772-Secondary
Disk Port Address
Assignment Conflict
None Address assignment conflict.
Internal and external hard drive
controllers are both assigned to
the secondary address.
Run the System Configuration
Utility and correct.
1773-Primary Fixed
Disk Port Assignment
Conflict
None Hard disk drive error Run the System Configuration
Utility and correct.
1774-Slot X Drive
Array Obsolete data
found in Array
Accelerator.
Select F1 to discard
contents of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
None SMART-2 Controller error The data found in the array
accelerator is older than data
found on the drives. Press F1 to
discard the older data in the
array accelerator and retain the
newer data on the drives.
1775-Slot X Drive
Array ProLiant
Storage System Not
Responding SCSI
Port (y): Check
storage system
power switch and
cables. Turn the
system power off
while checking the
ProLiant power and
cable connections,
then turn the system
power back on to
retry.
None Storage system problem Turn off power to the system.
Check the external ProLiant
power switch external drives
must all be powered up before
or at the same time as the main
system. Check cables. If the
retry does not help, try
replacing the cable, ProLiant
firmware, ProLiant backplane,
or the Smart Array Controller.
1776-Slot X Drive
Array SCSI Bus
Termination Error
Internal and external
drives cannot both be
attached to the same
SCSI port.
SCSI port Y: Check
cables
RESUME = F1 Key
None External and internal connectors
of the specified SCSI ports are
both attached to drives. The
indicated SCSI bus is disabled
until this problem is resolved.
The SCSI bus is not properly
terminated when internal and
external drives are attached
concurrently to the same SCSI
bus.
1. Turn off power to the
server.
2. Verify cabling to the
specified port.
Reconfigure the drives as
indicated.
continued