ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

Diagnostics and Troubleshooting 3-17
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1777-Slot X Drive
Array – ProLiant
Drive Storage
Enclosure Problem
Detected (followed by
one or more of the
following):
SCSI Port Y: Cooling
Fan Malfunction
Detected
SCSI Port Y:
Overheated Condition
Detected
SCSI Port Y:
Side-Panel must be
Closed to Prevent
Overheating
SCSI Port Y:
Redundant Power
Supply Malfunction
Detected
SCSI Port Y: Wide
SCSI Transfer Failed
SCSI Port Y: Interrupt
Signal Inoperative
(RESUME = F1 KEY)
None Temperature violation detected.
Cooling fan failure, internal
temperature alert or open side
panel
Check cooling fan operation by
placing your hand over the fan.
Check the internal plenum
cooling fan in tower servers or
storage systems. If the fan is
not operating, check for
obstructions and check all
internal connectors. If the unit’s
side panel was removed,
replace it.
When the ProLiant Storage
System power LED is amber
instead of green, this indicates
a redundant power supply
failure.
Check SCSI cables. Verify your
cabling against the diagrams in
your Compaq Smart Array
Controller user’s guide. If the
routing is correct, replace
cables on the specified port
until the POST message is
eliminated.
1778-Drive Array
resuming Automatic
Data Recovery
process
None This message displays whenever
a controller reset or power cycle
occurs while Automatic Data
Recovery is in progress.
No action necessary.
1779-Slot X Drive
Array – Replacement
drive(s) detected OR
previously failed
drive(s) now
operational:
Port Y: SCSI ID Z:
Restore data from
backup if
replacement drive X
has been installed.
None Intermittent drive failure and/or
possible loss of data
If this message appears and
drive X has not been replaced,
this indicates an intermittent
drive failure. This message also
appears once immediately
following drive replacement
whenever data must be restored
from backup.
1780-Disk 0 Failure None Hard drive/format error Run Diagnostics. Replace failed
assembly as indicated.
1781-Disk 1 Failure None Hard drive/format error Run Diagnostics. Replace failed
assembly as indicated.
continued