ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-18 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1782-Disk Controller
Failure
None Hard disk drive circuitry error Run Diagnostics. Replace failed
assembly as indicated.
1783-Slot X Drive
Array Controller
Failure
None ROM installation problem or array
accelerator board problem. If this
message displays immediately
following a ROM installation, the
ROM is defective or not installed
properly.
Check to see if:
The array accelerator board
is attached properly.
The array controller is firmly
inserted in its slot.
If the error recurs, upgrade the
System ROM. Otherwise,
replace the Smart Array
Controller.
1784-Drive Array
Drive Failure,
Physical Drive
None Defective drive and/or cables Check for loose cables. Replace
defective drive X and/or cables.
1785-Drive Array not
Configured (followed
by one or more of the
following):
None Configuration error See actions below.
Array Accelerator
Memory Size
Increased.
Run the Compaq System
Configuration Utility.
Configuration
information
indicates drive
positions beyond
the capability of
this controller.
This may be due
to drive
movement from a
controller that
supports more
drives than the
current controller.
To avoid data loss, turn the
system power off and reattach
the drives to the original
controller.
Configuration
information
indicates drives
were configured
on a controller
with a newer
firmware version.
To avoid data loss, reattach the
drives to the original controller
or use Options ROMPaq to
upgrade the controller firmware
to the version of the original
controller.
Press F1 to resume.
Drive positions
appear to have
changed.
Run the Array Diagnostic Utility
if previous positions are
unknown. Then turn off system
power and move the drives to
their original positions.
continued