ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
Diagnostics and Troubleshooting 3-19
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
continue 1785-Drive
Array not Configured
(followed by one or
more of the
following):
None Configuration error See actions below.
Drive positions
cannot be
changed during
Capacity
Expansion.
Run the Array Diagnostic Utility
if previous positions are
unknown. Then turn off system
power and move the drives to
their original positions.
External Cable(s)
Attached to
Wrong SCSI Port
Connector(s).
Turn off system power and
swap SCSI power connectors to
prevent data loss.
No drives
detected.
Turn off system power and
check SCSI cable connections
to make sure the drives are
attached properly.
Run Compaq
Array
Configuration
Utility
Run the Compaq Array
Configuration Utility.
continued