ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

3-20 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1786-Slot 1 Drive
Array Recovery
Needed. The
following SCSI
drive(s) need
Automatic Data
Recovery: SCSI
Port 1: SCSI ID 0
Select F1 to continue
with recovery of data
to drive. Select F2 to
continue without
recovery of data to
drive.
-Or-
Slot 1 Drive Array
Recovery Needed.
Automatic Data
Recovery Previously
Aborted! The
following SCSI
drive(s) need
Automatic Data
Recovery: SCSI Port
1: SCSI ID 0
Select F1 to retry
Automatic Data
Recovery to drive.
Select F2 to continue
without starting
Automatic Data
Recovery data to
drive data to drive.
None System in Interim Data Recovery
mode. Data has not yet been
recovered.
Press F1 to allow Automatic
Data Recovery to begin. Data
will automatically be restored to
drive X now that the drive has
been replaced or now seems to
be working.
-Or-
1. Press F2 and the system
will continue to operate in
the Interim Data Recovery
mode.
The “previously aborted”
version of the 1786 POST
message will appear if the
previous rebuild attempt
was aborted for any
reason.
2. Run the Array Diagnostic
Utility (ADU) for more
information.
If the replacement drive
has failed, try using
another replacement drive.
-Or-
If the rebuild was aborted due to
a read error from another
physical drive in the array, back
up all readable data on the
array, run Diagnostics Surface
Analysis, and then restore data.
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive X
None Hard drive X failed or cable is
loose or defective. Following a
system restart, this message
reminds you that drive X is
defective and fault tolerance is
being used.
1. Check loose cables.
2. Replace defective cables.
3. Replace drive X as soon as
possible.
continued