ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-22 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1793-Drive Array
Array Accelerator
Battery Depleted
Data Lost
(Error message 1794
also displays.)
None While the system was in use,
power was interrupted while data
was in the array accelerator
memory. The array accelerator
batteries failed. Power was not
restored within 8 to 10 days.
Data in the array accelerator has
been lost.
Perform orderly system
shutdowns to eliminate data
remaining in the array
accelerator.
1794-Drive Array
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
None This is a warning that the battery
charge is below 75%.
Posted-writes are disabled.
Replace the array accelerator
board if batteries do not
recharge within 36 power-on
hours.
1795-Drive Array
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
None While the system was in use,
power was interrupted while data
was in the array accelerator
memory.
The data stored in the array
accelerator does not correspond
to this drive array.
Match the array accelerator to
the correct drive array, or run
the System Configuration Utility
to clear the data in the array
accelerator.
1796-Drive Array
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
None Array accelerator is defective or
has been removed.
1. Check that the array
accelerator is properly
seated.
2. Run the System
Configuration Utility to
reconfigure the Compaq
IDA-2 without the array
accelerator.
1797-Drive Array
Array Accelerator
Read Error Occurred.
Data in Array
Accelerator has been
lost. Array
Accelerator is
disabled.
None Hard parity error while reading
data from posted-writes
memory.
Enable array accelerator.
continued