ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-30 Compaq ProLiant ML530 Servers Maintenance and Service Guide
800899, Video Board Test Error Codes
The 800 series of diagnostic error codes identifies failures with video boards or system board
functions.
Table 3-9
Video Board Test Error Codes
Error Code Description Recommended Action
802-xx Video memory test failed.
824-xx Video text mode test failed.
1. Replace monitor and retest.
2. Replace the Advanced VGA board and retest.
3. Replace the system board and retest.
11001199, Serial Test Error Codes
The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board
or system board functions.
Table 3-10
Serial Test Error Codes
Error Code Description Recommended Action
1101-xx Serial port test failed.
1109-xx Clock register test failed.
1. Check the switch settings on the serial/parallel
interface board (if applicable) and retest.
2. Replace the serial/parallel interface board
(if applicable) and retest.
3. Replace the system board and retest.