ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-32 Compaq ProLiant ML530 Servers Maintenance and Service Guide
17001799, Hard Drive Test Error Codes
The 1700 series of diagnostic error codes identifies failures with hard drives, hard drive
controller boards, hard drive cabling, and system board functions. If the system uses a drive
array controller, see the Array Diagnostic Utility (ADU) section.
Table 3-12
Hard Drive Test Error Codes
Error Code Description Recommended Action
1700-xx Hard drive ID drive types test
failed.
1701-xx Hard drive format test failed.
1702-xx Hard drive read test failed.
1703-xx Hard drive write/ read/ compare
test failed.
1704-xx Hard drive random seek test
failed.
1705-xx Hard drive controller test failed.
1708-xx Hard drive format bad track test
failed.
1709-xx Hard drive reset controller test
failed.
1710-xx Hard drive park head test failed.
1715-xx Hard drive head select test failed.
1716-xx Hard drive conditional format test
failed.
1717-xx Hard drive ECC* test failed.
1719-xx Hard drive power mode test failed.
1736-xx Drive Monitoring failed.
1799-xx Invalid hard drive type failed.
1. Run the System Configuration Utility and verify the
drive type.
2. Replace the hard drive signal and power cables
and retest.
3. Replace the hard drive controller and retest.
4. Replace the hard drive and retest.
5. Replace the system board and retest.
* Error Checking and Correcting