ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

3-32 Compaq ProLiant ML530 Servers Maintenance and Service Guide
1700–1799, Hard Drive Test Error Codes
The 1700 series of diagnostic error codes identifies failures with hard drives, hard drive
controller boards, hard drive cabling, and system board functions. If the system uses a drive
array controller, see the “Array Diagnostic Utility (ADU)” section.
Table 3-12
Hard Drive Test Error Codes
Error Code Description Recommended Action
1700-xx Hard drive ID drive types test
failed.
1701-xx Hard drive format test failed.
1702-xx Hard drive read test failed.
1703-xx Hard drive write/ read/ compare
test failed.
1704-xx Hard drive random seek test
failed.
1705-xx Hard drive controller test failed.
1708-xx Hard drive format bad track test
failed.
1709-xx Hard drive reset controller test
failed.
1710-xx Hard drive park head test failed.
1715-xx Hard drive head select test failed.
1716-xx Hard drive conditional format test
failed.
1717-xx Hard drive ECC* test failed.
1719-xx Hard drive power mode test failed.
1736-xx Drive Monitoring failed.
1799-xx Invalid hard drive type failed.
1. Run the System Configuration Utility and verify the
drive type.
2. Replace the hard drive signal and power cables
and retest.
3. Replace the hard drive controller and retest.
4. Replace the hard drive and retest.
5. Replace the system board and retest.
* Error Checking and Correcting