ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

3-34 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-14
Advanced VGA Board Test Error Codes
continued
Error Code Description Recommended Action
2410-xx Video 640 × 200 mode test failed.
2411-xx Video screen memory page test
failed.
2412-xx Video gray scale test failed.
2414-xx Video white screen test failed.
2416-xx Video noise pattern test failed.
2417-xx Lightpen text mode test failed, no
response.
2418-xx ECG/VGC memory test failed.
2419-xx ECG/VGC ROM checksum test
failed.
2420-xx ECG/VGC attribute test failed.
2421-xx ECG/VGC 640 × 200 graphics
mode test failed.
2422-xx ECG/VGC 640 × 350 16-color set
test failed.
2423-xx ECG/VGC 640 × 350 64-color test
failed.
2424-xx ECG/VGC monochrome text mode
test failed.
2425-xx ECG/VGC monochrome graphics
mode test failed.
2431-xx 640 × 480 graphics test failure.
2432-xx 320 × 200 graphics (256-color
mode) test failure.
2448-xx Advanced VGA Controller test
failed.
2451-xx 132-column Advanced VGA test
failed.
2456-xx Advanced VGA 256-color test
failed.
1. Run the System
Configuration Utility.
2. Replace the monitor and
retest.
3. Replace the Advanced VGA
board or other video board
and retest.
4. Replace the system board
and retest.
2458-xx Advanced VGA bit BLT test.
2468-xx Advanced VGA DAC test.
2477-xx Advanced VGA data path test.
2480-xx Advanced VGA DAC test.
1. Run Setup.
2. Replace the system board
and retest.