ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-34 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-14
Advanced VGA Board Test Error Codes
continued
Error Code Description Recommended Action
2410-xx Video 640 × 200 mode test failed.
2411-xx Video screen memory page test
failed.
2412-xx Video gray scale test failed.
2414-xx Video white screen test failed.
2416-xx Video noise pattern test failed.
2417-xx Lightpen text mode test failed, no
response.
2418-xx ECG/VGC memory test failed.
2419-xx ECG/VGC ROM checksum test
failed.
2420-xx ECG/VGC attribute test failed.
2421-xx ECG/VGC 640 × 200 graphics
mode test failed.
2422-xx ECG/VGC 640 × 350 16-color set
test failed.
2423-xx ECG/VGC 640 × 350 64-color test
failed.
2424-xx ECG/VGC monochrome text mode
test failed.
2425-xx ECG/VGC monochrome graphics
mode test failed.
2431-xx 640 × 480 graphics test failure.
2432-xx 320 × 200 graphics (256-color
mode) test failure.
2448-xx Advanced VGA Controller test
failed.
2451-xx 132-column Advanced VGA test
failed.
2456-xx Advanced VGA 256-color test
failed.
1. Run the System
Configuration Utility.
2. Replace the monitor and
retest.
3. Replace the Advanced VGA
board or other video board
and retest.
4. Replace the system board
and retest.
2458-xx Advanced VGA bit BLT test.
2468-xx Advanced VGA DAC test.
2477-xx Advanced VGA data path test.
2480-xx Advanced VGA DAC test.
1. Run Setup.
2. Replace the system board
and retest.