HP ProLiant ML570 Generation 2 Server Memory Installation Guide
Memory
HP ProLiant ML570 Generation 2 Server Memory Installation Guide 1-31
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: b-ch1 Memory.doc
Codename: Seabiscuit Part Number: 279987-003 Last Saved On: 5/8/03 8:58 AM
Table 1-10: Memory LED States on a Properly Configured Memory Board
Memory Configuration
LED
Advanced ECC
(Standard)
Memory
Online Spare
Memory
Single-Board
Mirrored
Memory
Hot-Plug
Mirrored
Memory
Memory status Green Green Green Green
DIMM 1-8, if
populated
Green Green Green Green
“Online Spare”
text *
Off Green Off Off
Online spare
status
Off Green Off Off
Mirroring status Off Off Green Green
“Ready to
Hot Plug” LED
Off Off Off Green
* If two memory boards are installed, the online spare text is only illuminated for the memory board
in slot 1.
7. If any of the LEDs are illuminated solid amber, indicating a failed DIMM, or
flashing amber, indicating improper DIMM configuration, refer to the
HP Servers Troubleshooting Guide on the Documentation CD for instructions.
8. Close the hot-plug door.
9. If you have a tower-model server, close the front bezel door.