HP ProLiant ML570 Generation 2 Server Setup and Installation Guide

Server Configuration and Utilities
8-8 HP ProLiant ML570 Generation 2 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Wendy Wing File Name: i-ch8 Server Configuration and Utilities.doc
Codename: Time Bandit Part Number: 223960-002 Last Saved On: 8/22/02 11:17 AM
Mode 2: 1+1 Redundant Power Supply
This server will be set-up for 1+1 redundancy. This mode will only support
two configurations:
A server with a maximum of 2 CPUs and up to 12 drives and all PCI-X
slots populated.
A server with a maximum of 4 CPUs and up to 6 drives and all PCI-X
slots populated.
IMPORTANT: The server will be redundant under these two configurations only. Any
deviation from these configurations does not guarantee full power redundancy and will be at
your own risk. This is your last notification. You will need to re-boot your server for this change
to take effect.
Utility Language
The Utility Language enables you to set the display language for RBSU. The
following choices are available:
English
French
Italian
German
Spanish
Japanese
The following table contains the default settings for options in primary RBSU menus.