ProLiant ML570 Generation 4 Server Cabling Matrix

This matrix provides information on cables required to connect internal and external SCSI, SAS or USB options.
The ML570 G4 includes one Serial-Attached SCSI (SAS) cable for the connection of the system hard drives. To connect a tape drive
or external SCSI device, a second SCSI cable is required (included with tape drive). A USB cable can be used for some internal tape drives, as well. These
SCSI or USB cables are often contained in the kit for the option. Use this matrix to identify any additional cables that may be required.
Option
SCSI Connector
on the Option
Cable Type Included
with the Option Supported HBAs/Controllers Additional Cables Required
Internal Hot Plug Hard Drives
Serial Attached SCSI (SAS)/ATA
(SATA) - 2.5 inch only
SAS
No SAS/SATA cable
included with the option
The hot plug drive cage can be connected to one of the following:
Smart Array P400 (P/N 405132-B21)
Smart Array P600 (P/N 337972-B21)
Smart Array P800 (P/N 381513-B21)
No additional cables required
Internal Tape
DAT 40 SCSI
DAT 72 SCSI
Ultrium 232
Ultrium 448
Ultrium 920
DLT VS160
Ultrium 448 SAS
SAS
Internal 4-channel split
SAS Cable (included)
HP 8 Internal Port SAS HBA with RAID (347786-B21)
HP Smart Array P800/512 BBWC Controller (381513-B21)
Ultrium 920 SAS
SAS
Internal 4-channel split
SAS Cable (included)
HP 8 Internal Port SAS HBA with RAID (347786-B21)
HP Smart Array P800/512 BBWC Controller (381513-B21)
DAT 24 USB
DAT 40 USB
DAT 72 USB
External Direct Attach Storage
MSA 20 VHDCI VHDCI-VHDCI 3 ft Smart Array 642, 6402 and 6404
MSA 30 VHDCI VHDCI-VHDCI 12 ft Smart Array 642, 6402 and 6404 No additional cables required
MSA 50 SAS (8470) 2 m external SAS
Smart Array P600 (P/N 337972-B21)
Smart Array P800 (P/N 381513-B21)
No additional cables required
MSA 500 G2 VHDCI VHDCI-VHDCI 6 ft Smart Array 642 No additional cables required
MSA 1000 2x VHDCI
No SCSI or fibre cable
included
FCA2214
H
os
t
Ad
ap
t
er
(Li
nux,
Mi
croso
ft
32
-
bit
,
N
e
t
ware
)
P/N
281541-
B21
FCA2214DC Host Adapter (Linux, Microsoft OS 32-bit, Netware) Dual
Channel P/N 321835-B21
Windows 32-bit Single Channel PCI-X (Windows Server 2003, W2K) P/N
A7388A
Windows 32-bit Dual Channel PCI-X (Windows Server 2003, W2K) P/N
A7387A
HP StorageWorks FC2142SR HBA 4Gb PCI-e for Windows, Linux P/N
A8002A
HP StorageWorks FC2242SR DC HBA 4Gb PCI-e for Windows, Linux
P/N A8003A
2 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B21)
5 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B22)
15 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B23)
30 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B26)
50 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B27)
MSA 1500
2x VHDCI (supports
either one SCSI
channel or two
SATA)
No SCSI or fibre cable
included
FCA2214 Host Adapter (Linux, Microsoft 32-bit, Netware) P/N 281541-
B21
FCA2214DC Host Adapter (Linux, Microsoft OS 32-bit, Netware) Dual
Channel P/N 321835-B21
Windows 32-bit Single Channel PCI-X (Windows Server 2003, W2K)
P/N A7388A
Windows 32-bit Dual Channel PCI-X (Windows Server 2003, W2K) P/N
A7387A
HP StorageWorks FC2142SR HBA 4Gb PCI-e for Windows, Linux P/N
A8002A
HP StorageWorks FC2242SR DC HBA 4Gb PCI-e for Windows, Linux
P/N A8003A
2 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B21)
5 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B22)
15 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B23)
30 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B26)
50 m LC-LC Multi-Mode Fibre Channel Cable
(P/N 221692-B27)
Plugs into system board; for the location of the connector, refer to
documents or label under the cover
HP ProLiant ML570 Generation 4 Server Cabling Matrix
LVD wide 68-pin HD68-HD68 64-Bit/133-MHz Single Channel Ultra320 SCSI G2 (P/N 374654-B21) No additional cables required
USB 2.0 USB 2.0
No additional cables required

Summary of content (2 pages)