HP ProLiant SL160s G6 Server Maintenance and Service Guide

Physical and Operating Specifications 84
Table 14 Environmental Specifications
Item
Description
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr
LWad: 7.8 Bels
(operation mode for non-redundant fan)
LWad: 6.4 Bels
(idel mode for non-redundant fan)
LWad: 8.0 Bels
(operation mode for redundant fan)
LWad: 6.7 Bels
(idel mode for redundant fan)
Table 15 Hot-Plug Power Supply Specifications
Item Description
Dimensions (H x W x D) 38.48 mm x 86.36 mm x 190.52 mm
Weight (approximate)
1.1 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC /200 VAC to 240 VAC
Line frequency 50Hz – 60Hz
Rated input current Max: 10A
BTU rating For 750W power supply: 100V-240V~/9.0-4.5A
For 750W power supply high efficiency: 100V-240V~
/9.0-405A
For 1200W power supply: 100V~/9.4A, 110V-
120V~/9.9A, 200V-240V~/7.8A
For 1200W power supply high efficiency:
100V~/9.3A, 110V-120V~/9.5A, 200V-
240V~/6.6A
Power supply output power:
Rated steady state power
Maximum peak power
750W/1200W
N/A
Temperature range:
Operating
Storage/Shipping
+5° to +50°
40° to +85°
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing.
5% to 95% relative humidity, non-condensing