HP ProLiant SL160s G6 Server Software Configuration Guide
System BIOS configuration 39
In some cases an error message may include recommendations for troubleshooting or require that you
press the Enter key to display recommendations. Follow the instructions on the screen.
It is recommended that you correct the error before proceeding, even if the server appears to boot
successfully. If your system displays one of the messages marked below with an asterisk (*), write
down the code and message and contact your HP Customer Support provider.
When no POST error message is displayed but the server stops during POST, listen for beep codes.
Table 21 lists the most common POST error messages with their corresponding troubleshooting
recommendation.
Table 22
POST error message
601
Error: BMC Not Responding
605 BMC Has Detected Fatal Hardware Error
611 Internal User Area Of BMC FRU Corrupted
612
Controller Update 'boot block' Firmware Corrupted
613 Controller Operational Firmware Corrupted
620 Non-Redundant Fan Failure or Missing
621
Redundant Fan Configuration, One Fan Failure or Missing
622 Redundant Fan Configuration, Multiple Fans Failure or Missing
623 Temperature Violation Detected
Waiting 5 minutes for system to cool
Press ESC Key to resume booting without waiting for the system to cool
Warning: Pressing ESC is NOT recommended as the system may shutdown
unexpectedly
624 Power Supply Failure or Power Supply Unplugged
626 Update SDRR/Configuration Image failed
627 Invalid or Unknown SKU/Chassis ID
Please check Front panel, System ID Jumper or Riser card
Press F1 to Continue
628 Redundant Power Supply Mismatch
194 CPUID, Processor family are different
192 L3 cache size mismatch
197 Processor speeds mismatched
198 Processor QPI speed mismatch detected.
193 CPUID, Processor stepping are different
196 CPUID, Processor Model are different
195 Front side bus mismatch. System halted.
160 Processor missing microcode
005 CMOS Checksum Bad