HP ProLiant SL165z G7 Server Installation Sheet
HP ProLiant SL165z G7 Server
Installation Sheet
Second edition (April 2010)
Part number 602405-002
Important Safety Information
Les "Viktig sikkerhetsinformasjon" på dokumentasjons-CDen før du installerer dette produktet.
Læs dokumentet Vigtige sikkerhedsoplysninger på dokumentations-cd'en, før produktet installeres.
Prima dell'installazione, leggere sul CD le Informazioni importanti sulla sicurezza.
Tärkeisiin turvatietoihin" Documentation CD -levyllä ennen tuotteen asentamista.
Läs dokumentet Viktig säkerhetsinformation på dokumentations-cd:n innan du installerar denna produkt.
Identifying server components
Front panel components
Figure 1 Front Panel Components / 2 SL165z Servers
Item Description
1 Tray handle
2 Tray latch
3 SD reader port (optional)
4 Front panel USB 2.0 port 0/1
5 Serial port
6 GbE LAN port for NIC 4
7 VGA port
8 GbE LAN port for NIC 2
9 Power switch/LED
10 System health LED
11 GbE LAN port for NIC 1
12 Low-prolePCIexpansioncardslotcover
13 GbE LAN port for NIC 3
14 Mgmt port (optional)
15 Front UID LED/switch
Rear panel components
Figure 2 Rear Panel Components
Item Description
1 Power supply 2 cable socket
2 Power supply 1 cable socket
3 Rear UID LED
System board components
Figure 3 System Board Components
Item Description
1 System maintenance jumper
2 PCIex16slot
3 Processor 1
4 Mgmt card connector
5 DIMM slot 12 for processor 1
6 DIMM slot 1 for processor 1
7 DIMM slot 12 for processor 2
8 Processor 2
9 4-pin power connector
10 24-pin power connector
11 Fan connector 1
12 Fan connector 2
13 DIMM slot 1 for processor 2
14 Backplane I2C connector
15 8-pin power connector
16 Fan connectors 3/4
17 Fan connector 5
18 Internal USB 2.0 port
19 SD card USB 2.0 port
20 Front panel USB 2.0 port
21 SAS LED connector
22 Fan connectors 6/7
23 Mini-SAS connector for SATA
24 Power backplane control connector
25 Front panel header
26 TPM connector
27 PCIex4slot
28 ODD 2 SATA connector
29 ODD 1 SATA connector
30 3 V CMOS battery (CR2032)
31 NMI jumper
Servercongurationresources
In addition to this Installation Sheet, other resources are available for more
informationregardingthecongurationandmaintenanceofyourserver:
• For safety information and detailed procedures relating to installation of options,
refer to any installation instructions that came with the option, as well as the
HP ProLiant SL165z G7 Server Maintenance and Service Guide.
• For safety information and detailed procedures related to the rest of the steps
listedinthe“ConguringtheServer”section,refertotherelevantchapterofthe
HP ProLiant SL1000/6000 Series Server User Guide.
• ForinformationrelatingtosystemBIOScongurationandoperatingsystem
installation, refer to the relevant section of the HP ProLiant SL165z G7 Server
Software Conguration Guide.
• You can also access additional information and documentation from the HP
website at www.hp.com.
Servercongurationoverview
The steps listed below give an overview of the necessary setup procedures for
preparingtheHPProLiantSL165zG7Serverforoperation:
1. Connect the AC power cord and peripheral devices.
2. Power on the server.
3. Press“F10”toenterBIOSsetup.
4. Note the server BIOS version.
5. Verify the server BIOS version against the latest BIOS version listed for this server.
6. If you do not have the latest BIOS, update the BIOS now. Refer to the
HP ProLiant SL165z G7 Server Maintenance and Service Guide available on
theHPwebsite:www.hp.com.
Pre- and post-installation
procedures
When installing additional options in your HP ProLiant SL165z G7 Server, observe
thefollowingprocedures:
Pre-installation procedures
1. Turn off the server and all the peripherals connected to it.
2. Disconnect the AC power cord from the power supply cable socket located on
the server rear panel to reduce the risk of electrical shock.
3. Iftheserverisinstalledinarack,removetheserverandplaceitonaatsurface.
4. Remove the server from the chassis by following the procedures described later
inthe“Removingtheserver”section.
Post-installation procedures
1. Be sure all components are installed according to the described step-by-step
instructions.
2. Check to make sure you have not left loose tools or parts inside the server.
3. ReinstallthePCIcage,airbafe,peripherals,andsystemcablesthatyou
have removed.
4. Reinstall the server into the chassis.
5. ConnectallexternalcablesandtheACpowercordtothesystem.
6. Press the power button on the front panel to turn on the server.
Removing the server
You need to remove the server from the chassis before you can remove or replace a
server component.
CAUTION: When the servers are operational, tray blank 577723-001
(Option Kit P/N 579069-B21) must be installed in the server slot after
removal of the server.
Toremovetheserver:
1. Press the tray latch to release the tray handle.
2. Rotate the tray handle to disengage the power connector.
3. Pull the server tray assembly out of the chassis.
4. Insert the tray blank into the server slot.
Figure 4 Removing the Server
Figure 5 Installing the Tray Blank
Installing a hard drive
One server tray can accommodate two LFF or four SFF hard drives, and the chassis
can accommodate two server trays for up to four LFF or eight SFF hard drives. The
server supports both SAS and SATA hard drives.
CAUTION: Drives can be damaged by static electricity. Before handling
drives, touch an unpainted metal surface to discharge static electricity.