HP SUM does not deploy Brocade switch firmware updates greater than 7.2.0 if MAPS is enabled
Suggested Action: Disable MAPS before upgrading firmware to versions greater than 7.2.0.
HP SUM unexpectedly quits running if it tries to pull a component from the web that does not exist
Suggested Action: No action. This will be resolved in a future version.
HP SUM reports incorrectly that a baseline was not deleted in Console mode
Suggested Action: No action necessary. This will be fixed in a future version. This occurs if the baseline
you are deleting is in the same directory as additional packages that are not in the baseline.
HP SUM does not assign the baseline for a node when added by IP range
Suggested Action: Edit the node after it has been added to assign the baseline. This will be resolved
in a future version.
HP SUM quits working when you delete a baseline
Suggested Action: Wait until HP SUM finishes performing inventory on a baseline before you delete
the baseline.
HP SUM does not display some RPM components in a baseline
Suggested Action: Update the component from another tool.
HP SUM does not correctly report the number of updates downloaded from the HP website
Suggested Action: No action. This will be resolved in a future version.
Advanced filters do not work as expected when you create a custom baseline
Suggested Action: No action. This will be resolved in a future version.
HP SUM does not build source RPMs
Suggested Action: Build the source RPM outside of HP SUM and then add the RPM to a baseline. After
HP SUM performs inventory on the baseline, it can deploy the RPM. This is how HP SUM designed to
work.
HP SUM unexpectedly stops running when you disconnect an ISO that contains a baseline that has
been added to HP SUM
Suggested Action: Do not disconnect from an ISO that contains a baseline that has been added to HP
SUM while HP SUM is running.
HP SUM adds an empty Additional Package to a baseline if the directory includes a .zip file
Suggested Action: Do one of the following:
Do not assign the empty Additional Package to nodes.
Move the .zip file to a directory mapped to a baseline.
HP SUM does not create a custom baseline if there is not enough free space, but HP SUM displays a
message that the baseline was created
Suggested Action: Make sure there is enough free space before creating a custom baseline.
Component issues
iPDU node components do not display the Force option
Suggested Action: HP SUM does not support downgrading or rewriting components for an iPDU node.