HP Smart Update Manager 5.2 Release Notes

gawk 3.1.0-3 or later
sed 3.02-10 or later
pciutils-2.1.8-25.i386.rpm or later
Be sure that the following platform-specific compatibility libraries are also installed.
For Red Hat Enterprise Linux 5 x86 servers:
libnl (required for QLogic and Emulex drivers and firmware)
For Red Hat Enterprise Linux 5 AMD64/EM64T servers:
libnl (required for QLogic and Emulex drivers and firmware)
For SUSE Linux Enterprise Server 10 x86 servers:
libnl (required for QLogic and Emulex drivers and firmware)
For SUSE LINUX Enterprise Server 10 AMD64/EM64T servers:
libnl (required for QLogic and Emulex drivers and firmware)
e2fsprogs-32bit
NOTE: This library is graphical only, however, it is required to use HP SUM in Console mode.
fontconfig-32bit
For SUSE LINUX Enterprise Server 11 x86 servers:
libstdc++33-3.3.3-11.9.i586 or later
libnl (required for QLogic and Emulex drivers and firmware)
For SUSE LINUX Enterprise Server 11 AMD64/EM64T servers:
libstdc++33-32bit-3.3.3-11.9 or later
libnl (required for QLogic and Emulex drivers and firmware)
Enable the network ports that HP SUM uses. For more information, see “Network ports used by HP
SUM” (page 8).
Minimum requirements for Red Hat Enterprise Linux 6 servers
Ensure that each NIC has an IP address assigned. To get the IP address assigned to a NIC, enter
the dhclient command in the console, which launches the NIC interfaces and retrieves an IP
address. If a NIC does not have an IP address, HP SUM appears to hang on start up.
Red Hat Enterprise Linux 6 console mode
6 Prerequisites