HP ProLiant SL390s G7 1U Half-width Server Maintenance and Service Guide
Physical and operating specifications 75
Table 10 Physical dimensions
Item
Description
System board platform ATX (Advanced Technology Extended)
System board dimension 17.935’’x6.5’’
Dimensions (H x W x D)
(with bezel)
6.96 x 17.64 x 35.32 inch
Server weight (approximate) Full loading (all memory, hard drives, power supplies, and processors
installed) 68.1kg
Light loading (one piece of memory, one hard drive, and one processor
8 trays installed) 55.2kg
Table 11 Environmental specifications
Item
Description
Thermal output (maximum operating) 392 W/hr
System inlet temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an altitude derating of
1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct sustained sunlight.
Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or
above 86°F (30°C).
System inlet temperature
Nonoperating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative humidity (noncondensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb
temperature, noncondensing.
Relative humidity (noncondensing)
Nonoperating
10% to 95% relative humidity (Rh), 101.7°F (38.7°C) maximum wet
bulb temperature, noncondensing.
Altitude
Operating
10,000 ft (3050 m). This value may be limited by the type and number
of options installed. Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Altitude
Nonoperating
30,000 ft (9144 m). Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Acoustic noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).
Idle LWAd 7.7 LpAm 52.36dBA
Operating LWAd 7.7 LpAm 52.60dBA