HP ProLiant SL390s G7 4U Half-width Server Installation Sheet

HP ProLiant SL390s G7 4U Half-
width Server
Installation Sheet
Part number: 616893-002
March 2013 (Second Edition)
*616893-002*
616893-002
Important Safety Information
Les "Viktig sikkerhetsinformasjon" på dokumentasjons-CDen før du installerer dette produktet.
Læs dokumentet Vigtige sikkerhedsoplysninger på dokumentations-cd'en, før produktet installeres.
Prima dell'installazione, leggere sul CD le Informazioni importanti sulla sicurezza.
Tärkeisiin turvatietoihin" Documentation CD -levyllä ennen tuotteen asentamista.
Läs dokumentet Viktig säkerhetsinformation på dokumentations-cd:n innan du installerar denna produkt.
Identifying Server Components
Front Panel Components
Figure 1 Front panel components of the s6500 chassis with two SL390s 4U servers
Item Description
1 VGA port
2
Serial port
3 Power LED/SW
4
SFP PLUS connector
5 QSFP
6 Top: NIC 2 connector
Bottom: NIC 1/iLO 3 connector
7 USB connectors
8
UID LED/SW
9 iLO 3 network port
10
Front PCIe bracket (LP slot)
11 HDD 1
12 HDD 2
13
HDD 3
14 HDD 4
15 HDD 5
16
HDD 6
17 HDD 7
18
HDD 8
19 Health LED
Rear Panel Components
Figure 2 Rear panel components of the s6500 chassis with two SL390s 4U servers
Item Description
1 Power supply 1
2
Power supply 2
3 Power supply 3
4
Power supply 4
5 UID LED/SW
6 APM connector
7
Fan 1
8 Fan 2
9 Fan 3
10
Fan 4
11 Fan 5
12
Fan 6
13 Fan 7
14 Fan 8
Server Conguration Resources
In addition to this Installation Sheet, other resources are available for more
information regarding the conguration and maintenance of your server:
For safety information and detailed procedures relating to installation of options,
refer to any installation instructions that came with the option, as well as the
HP ProLiant SL390s G7 4U Half-width Server Maintenance and Service Guide.
For safety information, regulatory notices, and detailed procedures related
to the rest of the steps listed in the “Conguring the Server” section, refer
to the relevant chapter of the HP ProLiant SL390s G7 4U Half-width Server
User
Guide.
You can also access additional information and documentation from the
HP
website at http://www.hp.com/.
Server Conguration Overview
The steps listed below give an overview of the necessary setup procedures for
preparing the HP ProLiant SL390s 4U Half-width Server for operation:
1. Connect the AC power cord and peripheral devices.
2. Power up the server.
3.
Press F9 to enter BIOS setup.
4. Note the server BIOS version.
5. Verify the server BIOS version against the latest BIOS version listed for this
server on the HP website: http://www.hp.com.
6.
If you do not have the latest BIOS, update the BIOS now. Refer to the
HP ProLiant SL390s G7 4U Half-width Server User Guide available on the
HP website: http://www.hp.com.
7. Install a supported operating system of your choice. For detailed
procedures,
refer to the documentation provided by the operating system
vendor. For a list of operating systems supported by your ProLiant server,
go to http://www.hp.com/go/supportos.
Pre- and Post-installation
Procedures
When installing additional options in your HP ProLiant SL390s G7 4U Half-width
server, observe the following procedures:
Pre-installation Procedures
1. Turn off the server and all the peripherals connected to it.
2. Remove the server from the chassis by following the procedure described later in
the “Removing the server” section.
Post-installation Procedures
1. Be sure all components are installed according to the described step-by-step
instructions.
2.
Check to make sure you have not left loose tools or parts inside the server.
3. Reinstall the PCI riser, peripherals, and system cables that you have removed.
4. Reinstall the server into the chassis.
5. Connect all external cables to the system.
6.
Press the power button on the front panel to turn on the server.
Removing the Server
You need to remove the server from the chassis before you can remove or replace a
server component.
To remove the server:
1.
Press the latch to release the handle.
2. Rotate the handle to disengage the power connector.
3. Extend the server from the chassis until the release latch catches.
4. Firmly holding the server, press the release button.
5.
Remove the server from the chassis.
Figure 3 Removing the SL390s left server
Figure 4 Removing the SL390s right server
To install the server:
1. Install the server into the chassis and push the server until it to the end of the
chassis.
2.
Press the latch to secure the server to the chassis.
Figure 5 Installing the SL390s left server