Quick Setup Instructions HP ProLiant SL4500 Series (3 node)
Quick Setup Instructions
HP ProLiant SL4500 Series
Part Number: 711552-001
February 2013
Edition: 1
*711552-001*
711552-001
Translated versions
To view, select a language:
• English
(http://www.hp.com/support/SL4540_SL4545_3N_QSI_en)
• Français
(http://www.hp.com/support/SL4540_SL4545_3N_QSI_fr)
• Español
(http://www.hp.com/support/SL4540_SL4545_3N_QSI_sp)
• Deutsch
(http://www.hp.com/support/SL4540_SL4545_3N_QSI_gr)
•
(http://www.hp.com/support/SL4540_SL4545_3N_QSI_jp)
•
(http://www.hp.com/support/SL4540_SL4545_3N_QSI_sc)
Site requirements
Select an installation site that meets the detailed installation site requirements
described in the site planning guide on the Documentation CD and on the HP
website (http://www.hp.com).
Verifying the pallet contents
Item Description
1 HP ProLiant SL4500 Series chassis
2 Nodes (3)
3 Drive blank*
4 Drive*
5 Power supply blank*
6 Management module
7 Power supply*
8 I/O modules (3)
9 System fans (5)
10 Access panel
11 Rack rails and cable management arm**
12 Documentation CD**
* The quantity depends on the conguration ordered.
** Not shown
Chassis component identication
Before installing front or rear components into the chassis, review device bay
numbering for each component.
Front panel components
Item Description
1 Node 1
2 Node drives
3 LFF drive health LED
4 LFF drive UID
5 Drives controlled by node 1 Smart Array controller
6 Node 2
7 Drives controlled by node 2 Smart Array controller
8 Node 3
9 Drives controlled by node 3 Smart Array controller
10 Drive display boards
11 Node VGA connector
12 Node USB connectors
13 Node Power On/Standby button and system power LED
14 Node health LED
15 Node release button
16 Node UID LED button
Conguration rules
• Fans must be installed in all fan bays to meet thermal requirements.
• An I/O module must be installed in all I/O bays.
• A power supply or power supply blank must be installed in all power
supply bays.
Rear panel components
© Copyright 2013 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties
for HP products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Item Description
1 System fans
2 I/O module for node 1
3 Management module
4 I/O module for node 2
5 Power supplies
6 I/O module for node 3
Device bay numbering
Setting up the chassis
WARNING:The chassis is very heavy. To reduce the risk of personal
injury or damage to the equipment:
• Observe local occupational health and safety requirements and
guidelines for manual material handling.
• Remove all installed components from the chassis before installing or
moving the chassis.
• Use caution and get help to lift and stabilize the chassis during
installation or removal, especially when the chassis is not fastened
to the rack.
WARNING:To reduce the risk of personal injury or damage to the
equipment, you must adequately support the chassis during installation
and removal.
1. Select the proper location for setting up the chassis, based on requirements
provided in the HP ProLiant SL4500 Series Setup and Installation Guide.
2. Remove the packing materials from the pallet.
3. Remove any installed components from the chassis:
o Chassis drives
o Nodes
o System fans
o I/O modules
o Management module
o Power supplies
Installing the chassis
The chassis requires installation in a rack. Install the rack rails, and then install the
chassis and other components.
For more information, see the HP ProLiant SL4500 Series Setup and Installation
Guide and the Quick Deploy Rail System Installation Instructions that ship with the
rack hardware kit.
Installing the front components
CAUTION:To prevent improper cooling and thermal damage, do not
operate the HP ProLiant SL4500 Series unless all drive and device bays
are populated with either a component or a blank.