347222- 003
About This Device
These instructions show how to install an uninterruptible power
system (UPS). For detailed information about the UPS, refer to the
UPS user guide on the Power Products Documentation CD.
Important Safety Information
Before installing this product, read the Important Safety
Information guide included with the UPS kit.
Regulatory Compliance Identification
Numbers
For regulatory compliance certifications and identification
purposes, the UPS models are assigned a series number, also
identified on the Regulatory Compliance label located on the side
of the UPS. For certification information, always refer to the series
number EO3001.
NOTE: The rating label on the device provides the class (A or B) of the
equipment. Class B devices have a Federal Communications Commission
(FCC) logo or FCC ID on the label. Class A devices do not have an FCC logo
or FCC ID on the label. After you determine the class of the device, refer to
the UPS user guide for complete regulatory compliance notices.
Weight
136 kg
300 lb
WARNING: The UPS weighs 136 kg (300 lb) when fully
assembled. To prevent personal injury or damage to the
equipment:
• Observe local occupational health and safety
requirements and guidelines for manual material
handling.
• Obtain adequate assistance to lift and stabilize the
product during installation or removal. The UPS is
unstable when not fastened to the rails.
• Remove the battery module to reduce the overall
weight of the product.
Position
WARNING: To prevent personal injury or damage to the
equipment, take the following precautions when installing the
equipment:
• The UPS must be installed at the bottom of the rack. If
placed in the rack with existing equipment, the rack must be
reconfigured to allow installation of the UPS at the bottom
of the rack.
• The UPS must be mounted on the rails included in the UPS
kit. Use the rack template tool included in the kit to align
the rails.
Checking the Battery
Recharge Date
Before unpacking the UPS, check the battery recharge date
specified on the battery recharge date label that is affixed to the
shipping carton.
IMPORTANT: Do not use the battery if the recharge date has passed. If the
date on the battery recharge date label has passed without the battery being
recharged, contact an HP authorized service representative for directions.
NOTE: The following label is only an example date. The date on your carton
may be different.
Kit Contents
Documentation
• International Regulatory Compliance guide
• Important Safety Information guide
• Power Products Documentation CD
• Rack and Power Management Pack CD
• This document
Rails
• Rails, with mounting hardware
• Rack template tool 6U (347221-022)
UPS
• UPS chassis (with electronics module)
• Battery modules (2)
• Two front bezel pieces
Additional Hardware
The following items are supplied for shipping a rack with a UPS
installed:
• M6 nuts (4)
• M6 flat washers (4)
• M6 split washers (4)
Cables
• Two 16 A IEC-320 jumpers (242867-001)
• Two 10 A, 2-meter (6-foot) IEC-320 power cords
(142263-001)
• Two 10 A, 2.5-meter (8-foot) IEC-320 power cords
(142263-002)
• Two 10 A, 3-meter (10-foot) IEC-320 power cords
(142263-003)
• 3.66-meter (12-foot) UPS/computer interface cable
(295245-004)
Tools and Materials Required
A #2 Phillips screwdriver is required.
The following items are supplied with the rack:
• Screws
• Cage nuts
• Cage nut-fitting tool
Preparing for Installation
Unpacking the UPS
WARNING: To prevent personal injury or damage to the
equipment:
• Only use the lift-out tray to unload the UPS.
• Do not use the lift-out tray to transport or carry the UPS.
Transport the UPS to its installation location. Unpack the UPS near
the rack where it will be assembled, following the instructions on
the carton. Verify that all components are present.
Mounting the Rails
The UPS must be mounted on the fixed rails supplied with the unit.
Before beginning this installation process, review and adhere to the
following precautions.
WARNING: To prevent personal injury, verify that the rack
containing the UPS is stable. The following conditions must be
met:
• The leveling feet are extended to the floor.
• The full weight of the rack rests on the leveling feet.
• The stabilizing feet are attached to the rack if it is a
single-rack installation.
• The racks are coupled together if it is a multi-rack
installation.
• Only one component should be extended at a time. A rack
may become unstable if more than one component is
extended for any reason.
IMPORTANT: Do not power up the UPS until assembly is complete.