Installation Guide, First Edition: HP Lights Out Advanced / KVM Card
one core I/O card and one HP Lights-Out Advanced / KVM card, the HP Lights-Out Advanced
/ KVM card must be installed in I/O chassis 0.
For rx7640 or rx8640 servers with two core I/O cards, the HP Lights-Out Advanced / KVM card
can be installed in either I/O chassis (with only one HP Lights-Out Advanced / KVM card per
partition).
The following table lists examples of unsupported core I/O card configurations with the HP
Lights-Out Advanced / KVM card and possible solutions.
SolutionResultConfigurationServer
Move the HP Lights-Out
Advanced / KVM card to I/O
chassis 1.
Operating system does not boot
with this unsupported
configuration.
rx7640 • One core I/O card installed in
I/O chassis 1.
• HP Lights-Out Advanced /
KVM card installed in I/O
chassis 0.
Move the HP Lights-Out
Advanced / KVM card to I/O
chassis 0.
Operating system does not boot
with this unsupported
configuration.
rx8640 • One core I/O card installed in
I/O chassis 0.
• HP Lights-Out Advanced /
KVM card installed in I/O
chassis 1.
Supported PCI-X Slots
The following table lists supported mode-1 PCI-X slots for each supported server with either
PCI-X or PCI-X/PCIe backplanes.
Table 3-1 Mode-1 PCI-X Slots by Server and Backplane
PCI-X/PCIe BackplanePCI-X BackplaneServer
Slots 1, 2, 7Slots 1, 2, 7rx7640
1
Slots 1, 2, 7, 8Slots 1, 2, 7, 8rx8640
Slots 0, 1, 8, 9, 10, 11Slots 0, 1, 2, 3, 4, 7, 8, 9, 10, 11Superdome sx2000
2
1 Slot 8 must be occupied by a core I/O card for the LOA card to function.
2 Must be installed in slot 0 on Windows partitions.
Supported PCI-X Slots 9