HP StorageWorks B-Series Multi-protocol Router Blade Installation Guide (A7990-90002, June 2006)
Technical specifications34
Boot
In addition to POST, boot includes the following tasks after POST is complete:
1. Perform universal port configuration
2. Initialize links
3. Analyze fabric. If any ports are connected to other switches, the switch participates in a fabric
configuration
4. Obtain a domain ID and assigning port addresses
Regulatory Certifications
Table 8 lists the safety and EMC (electromagnetic compatibility) specifications for which the B-Series
MP Router blade is certified.
Table 8 EMC Certifications
Country Safety Specification EMC Specification
Canada CSA 22.2 No. 60950 Third Ed. CSA 108.8 Class A
United States UL 60950 Third Ed., Info. Tech.
Equip.
EN55022 Class A
FCC Part 15, Subpart B (CFR title 47), Class
A
Japan IEC 60950+A1+A2+A3+A4+A11 EN55022 Class A
EN 61000-3-2 Harmonics (JEIDA Limits)