HP StorageWorks SAN Virtualization Services Platform administrator guide (5697-0109, July 2009)

3 Zoning
Zoning is used to partition a fabric into logical groups of devices that can access members of the
zone and are restricted from accessing devices not in the zone. Because SAN Virtualization Services
Platform (SVSP) is only supported in dual-fabric SANs, it requires at least four zones per SAN, or two
per fabric as described in the following:
Fabric A front-end: server to DPM targets for fabric A
Fabric A back-end: DPM initiators, VSM, and arrays, for fabric A
Fabric B front-end: server to DPM targets for fabric B
Fabric B back-end: DPM initiators, VSM, and arrays, for fabric B
During initial installation, your solution may have been configured using some basic zoning rules. As
the configuration grows, it is necessary to replace the simple zoning with a more complex zoning
protocol. The reasons are buried in the implementation details of the Fibre Channel switches and
specifications. In practice, HP recommends basing all zones on the concept of a single initiator per
zone (see the HP StorageWorks SAN design reference guide). Therefore, the remainder of this chapter
describes other zoning protocols.
This document describes two options for replacing the basic zoning used during installation of the
SVSP system. The first is the capacity zoning protocol that builds a solution with the maximum number
of supported front-end virtual disks, servers, back-end LUs, and arrays. The other is called high
performance zoning, which is designed to get the maximum performance out of a few arrays.
For each of these zoning protocols, this guide describes the back-end zone consisting of the:
DPM-to-array zones
VSM-to-DPM zones
VSM-to-array zones
NOTE:
In each pairing is the initiator to its targets.
After the back-end zones, this guide describes the front-end zones, which consists of the server-to-DPM
zones.
NOTE:
Each DPM consists of 16 ports, divided into four groups of four ports. Each group of four ports is
called a quad. Each pair of quads within a DPM group has two server-to-DPM target ports and
two DPM initiator-to-array ports per fabric. To simplify the drawings and tables, this document
references the ports within a quad, and not the physical DPM port number. For example, the left-most
port of the DPM is labeled port 0 of the first quad. The left-most port of the second quad is also port
0 of that quad, while it is labeled port 5 (moving left to right on the DPM).
HP StorageWorks SAN Virtualization Services Platform administrator guide 49