SerialSCSI-00 (sasd) B.11.23.1003 Mass Storage Driver Release Notes

Corrective Action: Before you shut down the server, run ioscan and note the DSF
information for the failed disk.
For more information on replacing disks, see the HP 8 Internal Port SAS Controller and HP
Multi-Port Internal SAS Controller Support Guide at:
http://docs.hp.com/en/netcom.html
4.2 AH303A PCIe SC44Ge SAS Host Bus Adapter
Virtual Partitions do not boot in multi-initiator configurations under vPars A.4.05.
Virtual Partitions (vPars) version A.4.05 using an HP StorageWorks MSA60 or MSA70
enclosure do not boot if AH303A cards assigned to multiple virtual partitions are connected
to the same JBOD. Under the vPars I/O resource assignment rules, a host bus adapter cannot
be shared among multiple virtual partitions.
Corrective Action: This issue is corrected in vPars A.04.06 (B.11.23.0809).
Virtual Partitions do not boot if hardware reconfiguration changes the hardware path
under vPars A.4.05.
Virtual Partitions (vPars) using an HP StorageWorks MSA50/MSA60/MSA70 enclosure do
not boot if hardware paths change due to hardware reconfiguration. For more information
on the impacts of hardware reconfiguration, see the Ignite-UX and SAS Devices white paper
at:
http://www.hp.com/go/ignite-ux-docs
Corrective Action: This issue is corrected in vPars A.04.06 (B.11.23.0809).
There is a setboot command issue on specific servers.
The setboot -p/-a/-h command fails when issued on an AH303A adapter installed in
slots 3 or 4 on HP Integrity rx3600 and rx6600 systems.
Corrective Action: Install AH303A adapters in nonswitched slots. This issue is corrected in
patch PHKL_37869. You can download patches from the IT Resource Center at:
http://itrc.hp.com/
4 Known Problems and Limitations 5