SerialSCSI-00 (sasd) B.11.31.
© Copyright 2010 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides information about the March 2010 release of the SerialSCSI-00 bundle for HP-UX 11i v3. Changes from Edition 1 This edition includes the following changes: • • In Section 6.1, the required version of CommonIO is changed to B.11.31.1003. Links to documentation on the HP website have been updated.
Problems Fixed in Recent Versions Table 3 HP-UX 11i v3 September 2009 Fixes — SerialSCSI-00 B.11.31.0909 SR Number Description QXCR1000890780 Double system panic and shutdown daemon detects a hang condition. QXCR1000901313 The olrad -d command hangs on adapters supported by the sasd driver. QXCR1000911615 System panic when the data cable is disconnected from an HP StorageWorks MSA60 or MSA70 enclosure. Table 4 HP-UX 11i v3 March 2009 Fixes — SerialSCSI-00 B.11.31.
Click the link for your HP-UX version. This document is listed alphabetically in the “Setup and install — general” section. • Before replacing a failed disk, note its Device Special File (DSF) information. If you shut down a server to replace a failed disk offline, the DSF of the failed disk is not visible in the ioscan utility when the server restarts. The DSF is required by the replace_tgt command to rebuild the array with the new disk.
NOTE: If you remove the dynamically loaded sasd driver while it is in use, or if you remove the statically loaded sasd driver at any time, you must perform a reboot. This is normal behavior under these conditions and is not affected by patch PHCO_36356. • System panic when downgrading the sasd driver. CAUTION: Installing an older version of the sasd driver downgrades the adapter firmware. This can cause RAID volumes in the system to become degraded.
(Replace X with the instance of the SAS controller.) • Swapping Spare Disks Consider the following when you swap physical disks in a RAID volume controlled by an HP 8 Internal Port SAS Controller: — Before swapping a spare disk, delete it using sasmgr(1M): sasmgr delete -D /dev/sasdX -q raid -q spare (Replace X with the instance of the SAS controller.
7 Related Information The latest documentation for Common IO and SAS host bus adapters is available in English at: http://www.hp.com/go/hpux-iocards-docs Click the link for your HP-UX version. • Installation guides are listed alphabetically in the “Setup and install — general” section. • Release notes are listed alphabetically in the “Getting started” section. • Support guides are listed alphabetically in the “User guide” section.