SerialSCSI-00 (sasd) B.11.31.1003 Mass Storage Driver Release Notes, Edition 2 (June 2010)
Problems Fixed in Recent Versions
Table 3 HP-UX 11i v3 September 2009 Fixes — SerialSCSI-00 B.11.31.0909
DescriptionSR Number
Double system panic and shutdown daemon detects a hang condition.QXCR1000890780
The olrad -d command hangs on adapters supported by the sasd driver.
QXCR1000901313
System panic when the data cable is disconnected from an HP StorageWorks MSA60 or
MSA70 enclosure.
QXCR1000911615
Table 4 HP-UX 11i v3 March 2009 Fixes — SerialSCSI-00 B.11.31.0903
DescriptionSR Number
Potential system hang issue during abort for an I/O.QXCR1000865554
System panics while posting an ABORT request when chip is in transient state.QXCR1000837729
Table 5 HP-UX 11i v3 December 2008 Fixes — SerialSCSI-00 B.11.31.0812
DescriptionSR Number
Unmapped WSIO Memory causes MCA.QXCR1000878007
Table 6 HP-UX 11i v3 September 2008 Fixes — SerialSCSI-00 B.11.31.0809
DescriptionSR Number
System panic when Scatter/Gather elements exceed the limit.QXCR1000806108
4 Known Problems and Limitations
This section provides a list of problems and limitations known to HP when these release notes
were published. If workarounds are available, they are included.
4.1 HP 8 Internal Port SAS Controller and HP Multi-Port Internal SAS Controller
• Updating the adapter firmware to version 1.23.33 or later might change the target ID of
disk devices.
This occurs on HP Integrity rx2660, rx3600, and rx6600 servers when an Integrated RAID
volume is configured on the controller and you perform one of the following actions:
— Update the adapter firmware offline using sasflash.efi.
— Boot to an HP-UX or Ignite-UX disk containing the sasd driver from one of the following
releases, which download firmware version 1.23.33 to the adapter during boot:
◦ B.11.23.0712
◦ B.11.31.0712
Changing the target ID might cause physical disks, including the OS boot disk, to become
inaccessible. If some of the disks from the IR volume are inaccessible, the volume can become
degraded or fail.
NOTE: The target ID change does not occur on systems without a RAID-1 volume. It also
does not occur on Bl860c servers with the HP Multiport SAS Controller.
For detailed information on how to avoid or correct this problem, see Updating Internal SAS
Controller Firmware to Version 1.23.33 Or Later at:
http://www.hp.com/go/hpux-iocards-docs
4