SerialSCSI-00 (sasd) B.11.31.1003 Mass Storage Driver Release Notes, Edition 2 (June 2010)
(Replace X with the instance of the SAS controller.)
• Swapping Spare Disks
Consider the following when you swap physical disks in a RAID volume controlled by an
HP 8 Internal Port SAS Controller:
— Before swapping a spare disk, delete it using sasmgr(1M):
sasmgr delete -D /dev/sasdX -q raid -q spare
(Replace X with the instance of the SAS controller.)
After the new disk is installed, use sasmgr(1M) to configure the new disk as spare:
sasmgr add -D /dev/sasdX -q raid -q spare -q enc_bay=<enc>:<bay>
(Replace X with the instance of the SAS controller and <enc>:<bay> with the location
of the disk to be configured as spare.)
— By default, RAID volumes are created with Auto-Configure enabled. If you swap a
physical disk that is part of a RAID volume, a resync begins and data on the new disk
is lost. Do not insert a replacement disk unless you are sure that existing data is backed
up.
6 Compatibility and Installation Requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, see the HP 8 Internal Port SAS Controller and HP Multi-Port
Internal SAS Controller Support Guide or the AH303A PCIe SC44Ge SAS Host Bus Adapter for Integrity
Servers Support Guide, at:
http://www.hp.com/go/hpux-iocards-docs
Click the link for your HP-UX version. Support guides are listed alphabetically in the “User
guide” section.
6.1 Required Software
The SerialSCSI-00 bundle depends on SAS-COMMON, which is delivered as a part of the
CommonIO bundle. Before installing SerialSCSI-00, be sure that version B.11.31.1003 or later of
CommonIO is installed.
This version of SerialSCSI-00 requires version C.7.4.157 or later of Ignite-UX.
You can download these products from the Software Depot website:
http://www.hp.com/go/softwaredepot
Search for CommonIO and Ignite-UX.
6.2 Operating System and Version Compatibility
This release is specific for HP-UX 11i v3 (B.11.31).
6.3 Hardware Requirements
This version of SerialSCSI-00 runs on HP Integrity servers with the HP-UX 11i v3 (B.11.31)
operating system. For more information on supported systems, see the SAS Host Bus Adapters
Support Matrix at:
http://www.hp.com/go/hpux-iocards-docs
Click the link for your HP-UX version. Support Matrix documents are listed alphabetically in
the “General reference” section.
6 Compatibility and Installation Requirements 7