© Copyright 2010 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides information about the September 2010 release of the SerialSCSI-00 bundle for HP-UX 11i v3. 1 SerialSCSI-00 (sasd) Overview The SerialSCSI-00 bundle contains the sasd driver for the AH303A PCIe SC44Ge SAS Host Bus Adapter, and the core-only HP 8 Internal Port SAS Controller and HP Multi Port Internal SAS Controller. The sasd driver is always installed. 2 New and Changed Features in This Release 2.
Table 6 HP-UX 11i v3 September 2008 Fixes — SerialSCSI-00 B.11.31.0809 SR Number QXCR1000806108 Description System panic when Scatter/Gather elements exceed the limit. 4 Known Problems and Limitations This section provides a list of problems and limitations known to HP when these release notes were published. If workarounds are available, they are included. 4.1 HP 8 Internal Port SAS Controller and HP Multi-Port Internal SAS Controller • Updating the adapter firmware to version 1.23.
Under the vPars I/O resource assignment rules, a host bus adapter cannot be shared among multiple virtual partitions. Corrective Action: None. This issue is corrected in vPars A.05.03 (B.11.31.0803). • There is a setboot command issue on specific servers. The setboot -p/-a/-h command fails when issued on an AH303A adapter installed in slots 3 or 4 on HP Integrity rx3600 and rx6600 systems. Corrective Action: Install AH303A adapters in nonswitched slots. This issue is corrected in patch PHKL_37278. 4.
0xe0000000009dbfa0 0xe000000000c7d320 0xe0000000017716b0 End of Stack Trace wsio_init_end+0x40 io_virt_mode_config+0x1c0 DoCalllist+0x3a0 This problem happens on HP Integrity rx2600, rx3600, rx6600, BL860c systems, and on rx7640 and rx8640 systems with AH303A adapters installed. Corrective Action: Reboot the system to recover from the panic. 5 Recommendations This section provides recommendations for highest performance and reliability.
This version of SerialSCSI-00 requires version C.7.4.157 or later of Ignite-UX. You can download these products from the Software Depot website: http://www.hp.com/go/softwaredepot Search for CommonIO and Ignite-UX. 6.2 Operating System and Version Compatibility This release is specific for HP-UX 11i v3 (B.11.31). 6.3 Hardware Requirements This version of SerialSCSI-00 runs on HP Integrity servers with the HP-UX 11i v3 (B.11.31) operating system.