SerialSCSI-00 (sasd) B.11.31.1209 Mass Storage Driver Release Notes HP-UX 11i v3

(Replace X with the instance of the SAS controller.)
Swapping Spare Disks
Consider the following when you swap physical disks in a RAID volume controlled by an HP
8 Internal Port SAS Controller:
Before swapping a spare disk, delete it using sasmgr(1M):
sasmgr delete -D /dev/sasdX -q raid -q spare
(Replace X with the instance of the SAS controller.)
After the new disk is installed, use sasmgr(1M) to configure the new disk as spare:
sasmgr add -D /dev/sasdX -q raid -q spare -q enc_bay=<enc>:<bay>
(Replace X with the instance of the SAS controller and <enc>:<bay> with the location
of the disk to be configured as spare.)
By default, RAID volumes are created with Auto-Configure enabled. If you swap a physical
disk that is part of a RAID volume, a resync begins and data on the new disk is lost. Do
not insert a replacement disk unless you are sure that existing data is backed up.
6 Compatibility and installation requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, see the HP 8 Internal Port SAS Controller and HP Multi-Port
Internal SAS Controller Support Guide or the AH303A PCIe SC44Ge SAS Host Bus Adapter for
Integrity Servers Support Guide, at:
http://www.hp.com/go/sas-hba-docs
Click the link for your HP-UX version. Support guides are listed alphabetically in the “User guide
section.
6.1 Required software
The SerialSCSI-00 bundle depends on SAS-COMMON, which is delivered as a part of the
CommonIO bundle. Before installing SerialSCSI-00, be sure that version B.11.31.1103 or later
of CommonIO is installed.
This version of SerialSCSI-00 requires version C.7.4.157 or later of Ignite-UX.
You can download these products from the Software Depot website:
http://www.hp.com/go/softwaredepot
Search for CommonIO and Ignite-UX.
6.2 Operating system and version compatibility
This release is specific for HP-UX 11i v3 (B.11.31).
6.3 Hardware requirements
This version of SerialSCSI-00 runs on HP Integrity servers with the HP-UX 11i v3 (B.11.31) operating
system. For more information on supported systems, see the SAS Host Bus Adapters Support Matrix
at http://www.hp.com/go/sas-hba-docs.
Support Matrix documents are listed alphabetically in the “General reference section.
7 Related information
The latest documentation for Common IO is available in English at http://www.hp.com/go/
common-io-docs. The latest documentation for SAS host bus adapters is available in English at
http://www.hp.com/go/sas-hba-docs.
6