HP scsiU320-00 (mpt) B.11.31.
© Copyright 2009 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides information about the September 2009 release of the scsiU320-00 bundle for HP-UX 11i v3. 1 HP scsiU320-00 Overview The scsiU320-00 bundle contains the mpt driver, which supports the HP A7173A PCI-X Dual Channel Ultra320 SCSI Host Bus Adapter and the HP AB290A PCI-X 2-Port U320 SCSI and 2-Port Gigabit Ethernet Combination Card. Additionally, the mpt driver supports multiple servers using U320 SCSI Core I/O solutions. 1.
Problems Fixed in Recent Versions Table 3 HP-UX 11i v3 March 2009 Fixes — scsiU320-00 B.11.31.0903 SR Number Description QXCR1000860692 MPT driver does not update stat counters for outstanding I/Os and bytes written. QXCR1000858781 System panics during probe after a controller reset. Table 4 HP-UX 11i v3 September 2008 Fixes — scsiU320-00 B.11.31.0809 Reference Description QXCR1000593713 System panics during colad KFT test on debug kernel.
Use Help to get more information. Disk Expert>fu -- CAUTION -The Format Unit command will destroy all user data on the disk drive. The command can also take a long time to execute. Enter Cancel, Help, or OK: [Cancel] OK -- Expert tool: Format Unit for device SCSI Disk on path 0/2/1/1.2.0. -Format Options * 1 Retain both Primary and Growing Defect List (p_g_list) 2 Retain only the Primary Defect List (p_only) Enter selection: [p_g_list] 1 The format operation on SCSI Disk at path 0/2/1/1.2.
1. To shut down Online Diagnostics, use the monconfig command. For example: # /etc/opt/resmon/lbin/monconfig ============================================================================ =================== Event Monitoring Service =================== =================== Monitoring Request Manager =================== ============================================================================ EVENT MONITORING IS CURRENTLY ENABLED. EMS Version : A.04.20.31.02 STM Version : D.04.
4. • To restart Online Diagnostics, use the monconfig command. From the Monitoring Request Manager Main Menu, select the option to enable monitoring. Unnecessary reboot occurs when removing the mpt driver. If you use the swremove command to remove the dynamically loaded mpt driver, the Critical Resource Analysis (CRA) can fail. This causes swremove to incorrectly reboot the system.