Designing Disaster Recovery Clusters using Metroclusters and Continentalclusters, Reprinted October 2011 (5900-1881)

Figure 78 Sample Multi-Target Bi-Link Configuration
Sample Raid Manager Configuration on a DC1 NodeA (multi-target Bi-Link)
HORCM _MON
#ip_address service poll(10ms) timeout(10ms)
NodeA horcm0 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
/dev/rdsk/c6t12d0 /dev/rdsk/c9t12d0
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
dg12 dg12_d0 CL3-E 6 5
dg13 dg13_d0 CL3-E 6 5 h1
HORCM _INST
#dev_group ip_address service
dg12 NodeB.dc2.net horcm0 # communicate with DC2 nodes
dg13 NodeC.dc3.net horcm0 # communicate with DC3 nodes
Sample Raid Manager Configuration on a DC2 NodeB (multi-target Bi-Link)
HORCM _MON
#ip_address service poll(10ms) timeout(10ms)
NodeB horcm0 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
/dev/rdsk/c21t8d0 /dev/rdsk/c24t8d0
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
dg12 dg12_d0 CL1-A 13 1
#Phantom device group dg23
dg23 dg23_d0 CL1-A 13 1 h2
HORCM _INST
Configuring an P9000 or XP 3DC DR Solution 433