HP StorageWorks 2000sa Modular Smart Array supported cable configurations (457746-002, August 2008)
two servers/one HBA per server/single path
• 128 LUNs Max to Server 1
• 128 LUNs Max to Server 2
IMPORTANT:
You may not exceed 255 LUNs per MSA2000sa.
Dual controller configurations
one server/one HBA/dual path
• 128 LUNs Max to Server 1
one ser ver/two H BAs/dual path
• 255 LUNs Max to Server 1
two ser
vers/one HBA per server/single path
• 128 LU N
s Max to Server 1
• 128 LU N
s Max to Server 2
IMPORTANT:
You may not exceed 255 LUNs per MSA2000sa.
two servers/one HBA per server/dual path
• 128 LU N s M a x t o Se r ve r 1
• 128 LU N s M a x t o Se r ve r 2
• Thesecanbethesame128LUNSifitiseither:
•2-nodeclusterconfiguration
• a separate set of 128 LUNS and the servers are not clustered
IMPORTANT:
You may not exceed 255 LUNs per MSA2000sa.
two servers/two HBAs per ser ver/dual path
• 255 LUNs Max shared between Servers 1 and 2
NOTE:
there is a max of 255 LUNs shared between the 2 servers in a
clusterandamaximumof255LUNscombinedbetweenthe2
servers in a non-cluster (example, Server 1 has 192, Server 2
has 63)
four servers/one HBA per server/single path
• AnynumberorcombinationofLUNscanbesharedamongfour
serversaslongasthetotaladdsuptonomorethan255LUNsand
no individual server is mapped to more than 128 LUNs.
• Four servers can have two separate 2-node clusters using128 LUNs
each,orone4-nodeclustersharing128LUNs
Page 2