To use RBSU:
1. Power up the server.
2. Press the F9 key when prompted during system startup.
The main ROM-Based Setup Utility screen is displayed.
Figure 6-1: Main ROM-Based Setup Utility screen
3. Configure your system. (For detailed instructions, refer to the Compaq ROM-
Based Setup Utility User Guide.)
4. Select Boot Controller Order on the main RBSU screen and follow the on-
screen prompts to set the boot controller.
5. When you have finished using the utility, press the Esc key, and then press the
F10 key to confirm that you want to exit RBSU.
Using ORCA
Part of the startup sequence of a server is the Power-On Self-Test (POST). If the
array controller in the server supports ORCA, POST temporarily halts and an ORCA
prompt message is displayed for about five seconds. (If ORCA is not supported, the
prompt message is not displayed and the system continues with the startup sequence.)
1. Power up the server and let the system startup sequence begin.
2. While the prompt message is on the screen, press the F8 key to start ORCA.