Advanced Data Guarding User Guide

2-2 Advanced Data Guarding for the Smart Array 5300 Controller Reference Guide
Compaq Confidential – Need to Know Required
Writer: John Turner Project: Advanced Data Guarding for the Smart Array 5300 Controller Reference Guide Comments: final draft
Part Number: 188270-xx1 File Name: c-ch2 Installation.doc Last Saved On: 12/11/00 12:04 PM
2. Turn off the server.
3. Turn off any peripheral devices attached to the server.
4. Unplug the AC power cord from the outlet, then from the server.
5. Disconnect any peripheral devices from the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the
internal system components and hot-plug hard drives to cool before touching.
6. Remove or open the access panel.
7. Remove the Smart Array 5300 controller from the PCI slot.
Locating the Connector
The connector for the RAID ADG Enabler Module is located at the corner of
the controller board near the Array Accelerator connector socket (Figure 2-1).
Figure 2-1. Location of the RAID ADG Enabler Module connector on the Smart
Array 5300 controller board
The module attaches to the controller board with the narrow tab (circled in
Figure 2-2) nearest to the corner of the controller board. This tab can be
pressed outwards during installation to allow the module to be more readily
inserted into the board. The clips at each end of the module fit into the slots on
the board.