Embedded Compaq Smart Array 5i Plus Controller Installation Instructions For Compaq ProLiant ML370 Generation 2 Servers

Table 1: Battery Module LED Descriptions
Server status LED color LED status Battery module
status
Server is on and
has normal run
time
Green On Fast charging
Green Off Trickle charging
Amber On Short in the
connection of one or
more of the four
button cells within
the battery module
Amber Blinking Open in the circuit
between the positive
and negative
terminals of the
battery module
Amber Off Battery module
status is normal
Server is on and
is in the first
30 seconds after
powerup
Amber
and green
On Temporary lockout
state; data was lost
due to cable being
detached
Server is off and
is in data
retention mode
Amber Blinking
every 15
seconds
User data held in
write cache is being
backed up
Installation Procedure
Instructions for installing the Smart Array 5i Plus controller and battery module in the server are given on
the reverse side of this poster.
For further information about installation of the controller or the battery module:
1. Go to
www.compaq.com/smartarray.
2. In the controller matrix, click Smart Array 5i Plus.
3. Click Support and Documentation in the left menu bar or further down the page.