Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide

POST Error Messages
F-4 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages continued
Message Description Meaning and Recommended Action
1729 Slot 1 drive array
disk performance
optimization scan in
progress RAID 4/5
performance may be
higher after
completion.
This message is normal following the initial
configuration of RAID 4 or RAID 5 logical drives.
This POST message will go away and
performance of the controller will improve after the
parity data has been initialized by ARM (an
automatic process that runs in the background on
the controller).
1753 Slot x drive array
array controller
maximum operating
temperature exceeded
during previous power
up.
This message appears at the next power-up if the
controller locks due to excessive temperature.
Check for proper operation of the server cooling
fan.
1754 Slot z drive array
RAID ADG drive(s)
configured but ADG
Enabler Module is
detached or defective.
Please check for
detached ADG
Enabler Module. Array
accelerator is
temporarily disabled.
An operational ADG Enabler Module must be
attached whenever RAID ADG volumes are
configured or the array accelerator will be
disabled. Replace the ADG Enabler Module.
1755 Slot z drive array
ADG Enabler Module
appears to be
defective. Please
replace the ADG
Enabler Module.
Replace the defective ADG Enabler Module, or
remove it if it is not needed (that is, if no RAID
ADG logical drives are configured).
1756 Slot x redundant
controllers are not the
same model.
The redundant controllers are not of the same
model. Use two like model controllers for
redundancy.
continued