Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide

POST Error Messages
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide F-7
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages continued
Message Description Meaning and Recommended Action
1768 Slot x drive array
resuming logical drive
expansion process.
No action required. This message appears
whenever a controller reset or power cycle occurs
while array expansion is in progress.
1769 Slot x drive array
drive(s) disabled due
to failure during
expansion (possibly
followed by additional
details).
Data has been lost while expanding the array;
therefore, the drives have been temporarily
disabled. Press the F2 key to acknowledge the
data loss and re-enable the logical drives. Restore
data from backup. If the array accelerator has
failed, replace the array accelerator board after the
capacity expansion process has terminated. Never
turn off the system and replace the array
accelerator if capacity expansion is in progress.
1770 Slot x drive array
critical drive firmware
problem detected
please upgrade
firmware on the
following drive(s) using
Options ROMPaq
(available from
www.compaq.com):
SCSI port (y) SCSI ID
(x)
The indicated drives are running firmware that may
cause intermittent problems. Use the Options
ROMPaq utility to upgrade firmware on all drives
to the latest revision.
continued