POST Error Messages
F-10 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages continued
Message Description Meaning and Recommended Action
1779 Slot x drive array
replacement drive(s)
detected or previously
failed drive(s) now
appear to be
operational:
Port (y): SCSI ID (x)
Restore data from
backup if replacement
drive x has been
installed.
If this message appears and drive x has not been
replaced, an intermittent drive failure has occurred.
This message also appears once immediately
following drive replacement before data is restored
from backup.
1783 Slot x drive array
controller failure.
If this message appears immediately following a
ROM installation, the ROM is either defective or
not installed properly. Check that the controller is
firmly inserted in its slot. Check for improper
cabling or SCSI ID conflicts. Try upgrading the
system ROM. Otherwise, replace the array
controller.
1784 Slot x drive array drive
failure. The following
SCSI drive(s) should
be replaced:
SCSI port (y) SCSI ID
(x)
Check for loose cables. Replace defective drive x
and/or cable(s).
continued