Drive Arrays and Fault Tolerance
C-10 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: l-appc Drive Arrays and Fault Tolerance
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:51 PM
Table C-1: Summary of RAID Methods continued
RAID 0 RAID 1+0 RAID 5
Tolerates failure
of one physical
drive?
No Yes Yes
Tolerates
simultaneous
failure of >one
physical drive?
No Only if no two
failed drives are
in a mirrored
pair
No
Read
performance
High High High
Write
performance
High Medium Low
Relative cost Low High Medium
*Values for usable drive space are calculated with these assumptions:
All physical drives in the array have the same capacity.
Online spares are not used.
No more than 14 physical drives are used for RAID 5. (This number is
recommended so that the risk of logical drive failure is kept low. See
Appendix D for further information.)
Table C-2: Choosing a RAID Method
Most Important Also Important
Suggested RAID
Level
I/O performance RAID 1+0
Cost effectiveness
I/O performance
RAID 5 (RAID 0 if fault
tolerance is not
required)
I/O performance
Cost effectiveness
RAID 5 (RAID 0 if fault
tolerance is not
required)
Fault tolerance RAID 1+0