HP Smart Array E500 Controller User Guide

Diagnosing array problems 29
LED ID Color LED name and interpretation
8 Green CR7: Idle Task LED. This LED, together with LED 7, indicates the amount of
controller CPU activity. For details, see the following table.
Controller CPU activity level LED 7 status LED 8 status
0–25% Off Flashing
25–50% Flashing Off
50–75% On steadily Off
75–100% On steadily On steadily
Battery pack LEDs
Item ID Color Description
1 Green System Power LED. This LED glows steadily when the
system is powered up and 12 V system power is
available. This power supply is used to maintain the
battery charge and provide supplementary power to the
cache microcontroller.
2 Green Auxiliary Power LED. This LED glows steadily when 3.3V
auxiliary voltage is detected. The auxiliary voltage is used
to preserve BBWC data and is available any time that the
system power cords are connected to a power supply.
3 Amber Battery Health LED. To interpret the illumination patterns of
this LED, see the following table.
4 Green BBWC Status LED. To interpret the illumination patterns of
this LED, see the following table.