RAID 1: breaking mirrors and rebuilding drives, 4th Edition
3
10. Power off the server.
11. Remove the physical drives that constitute one of the new arrays.
IMPORTANT
If you do not remove one of the arrays, the OS cannot
distinguish between the two new arrays when the OS restarts
because the arrays will be identical.
12. Restart the OS.
Recombining a split mirrored array using ACU
Complete the following steps to re-mirror an array using ACU:
1. Take the server offline and insert the CD or bootable USB drive that contains the ACU (typically
SmartStart) into an appropriate media drive.
2. Restart the system, booting to the CD or bootable USB drive.
3. Select the HP ACU from the Maintenance Operation menu.
4. Select the controller that contains the array you want to re-mirror.
5. In the Configuration View panel, select the array to use as the source in the re-mirrored array.
6. In the Available Tasks panel, click Re-Mirror Array.
7. Select the array to be mirrored to the source. This is usually the array previously split out of the
original mirrored array, but it can be another array of the correct size.
CAUTION
This process destroys all data on the second array.
8. Click OK.
9. Restart the OS after ACU finishes re-mirroring the array. The Smart Array controller will use the
rebuild process to synchronize the mirrored drives. You can boot the OS during the rebuild
process, but the logical drive will not be fault-tolerant until the rebuild finishes.
NOTE
The drive-online LED will blink during the rebuild synchronization
process. The rebuild is complete when the LED stops blinking
and turns solid green. A 300GB SAS (3.5” 15K) drive can take
up to 2 hours to rebuild a mirrored array (depending on the
number of IOPS the server is submitting to the controller).
Refer to the HP website to find more information or to download the Array Configuration Utility.